<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-31 03-15-10
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 61 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 66 kHz 16326 10,7620
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,6 dBr 4,74 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 66 kHz MIN: 11 kHz % above 76 kHz: 10,7620 Acquired: 2025/03/31 3.14.06 Total samples: 16326 Equivalent time: 0:13:36 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 6,2 dBr MIN: 2,6 dBr AVE: 4,74 dBr % above 12,2 dBr: 0,0 Last value: 4,5 dBr (2025/03/31 3.14.05) 03.00 03.02 03.04 03.06 03.08 03.10 03.12 03.14 0 2 4 6 Pm [dBr]